FGA50N100BNTD2
1000V, 50A NPT-Trench IGBT CO-PAK
Test Standards: - Moisture Sensitivity: NA
- Thermal Impedance: 1/40
- Physical Dimensions: TO-3PN
- ESD HBM: 5200
- ESD CDM: 2000
| General Information | | Device Marking(TOP MARK) | $Y&Z&3&K
FGA50N100
BNTD2
| | | Family Code | 0S4 | | | Package Type | TO-3PN | | | Package Description | MOLDED PACKAGE, TT-3P,3LDS | | | Pin Count | 3 | | | FIT | 133 | | | Die Fabrication | | Fabrication Process Identifier | SEE SPEC REV | | | Package Assembly* | | Thermal Impedance (Theta JA) | 40 | °C/Watt | | Thermal Impedance (Theta JC) | 1 | °C/Watt | | Moisture Sensitivity | NA | | | Electrical Test | | ESD Human Body Model (HBM) | 5200 | V | | ESD Charged Device Model (CDM) | 2000 | V | | Package Assembly* | |
|
| Wire Material | AL | | | Wire Diameter | 6.0 MIL | | | Wire Material | AL | | | Wire Diameter | 20.0 MIL | |
*If an attribute is listed twice, either can be used on the part.
|