FXL3SD206 is a voltage translator with multiplexing and de-multiplexing functions for SDIO devices. It is designed for voltage translation over a wide range of input and output levels, from 1.65V to 3.6V.
The multiplexing/de-multiplexing function of this device allows expansion of a host SDIO interface to two SDIO peripheral devices. When selected, each SDIO peripheral can communicate with the host through the same host interface. An alternative application allows two host devices to interface with a single SDIO peripheral.
Port A is intended to connect to a host device and the voltage level tracks the VDDA. Ports B and C are intended to connect to peripheral devices. Peripheral I/O voltage levels track either VDD_HI or VDD_LO as determined by the VDD_SEL pin. During normal operation, VDD_HI must be greater than or equal to VDD_LO. The CH_SEL, VDD_SEL, and OE pins are referenced to VDD_CON. Channel communication from either Port A to Port B or Port A to Port C is controlled by the CH_SEL pin.
The selected channel remains in 3-state until the VDD of each side reaches an active level and the OE pin reaches a valid high. Internal power-down circuitry places the selected channel of the device in 3-state if either side VDD removed.
The direction of data is controlled automatically by the device. No direction control pin is required. The device senses input signals on any port automatically and transfers the data to the corresponding output.
|