Find the controller that offers the optimum combination of standby power and operating efficiency for popular power levels with this reference chart.

| Design, simulation, analysis, no need for hardware prototype Complete flyback designs in minutes -- at no expense |
| FEB Product ID | Topology | Application | Featured Product(s) | Additional Products | Output Power (W) | Output (V/A) | Input Voltage Range (VAC) |
|---|---|---|---|---|---|---|---|
| FEBFAN6920MR_T02U120A | Dual Switch Flyback, PFC Boost | NB Adapter | 120 | 1 9/6.31 | 90-264 Vac | ||
| FEBFSL206MRN_H428v1 | Flyback | Motion Control and General Aux Power Supply, Smart Grid, Smart Meter | 5 | 5/1 | 90-264 Vac | ||
| FEBFSQ500L_H257v1 | Flyback | Motion Control and General Aux Power Supply, Smart Grid, Smart Meter | 2 | 5/0.4 | 90-264 Vac | ||
| FEBFAN6754AMR_CP450v1 | Flyback & Forward | NB Adapter | 65 | 19/3.42 | 90-264 | ||
| FEBFSB127H_T001 | Flyback & Forward | PC Pwr Stdby | 16 | 5/3.2 | 90-264 | ||
| FEBFSEZ1317WA_CH310v3 | Flyback & Forward | Mobile Phone Battery Charger | 3.5 | 5/0.7 | 90-264 Vac |
| Pout (Watts) | Input Voltage | Output Voltage Rated Current | Topology | Featured Products | Document Number |
|---|---|---|---|---|---|
| 5 | 90-264VAC | 5V/1A | PSR Flyback | FAN302HL | RD-350 |
| 16 | 90-264VAC | 5V/3.2A | Flyback | FSB127H | RD-FSB127H-T001 |
| 65 | 90-264VAC | 19V/3.42A | Flyback | FAN6756 | RD-FAN6756 |
| 90 | 90-264VAC | 12V/4.74A | Dual Switch Flyback | FAN6920MR FAN7382 FAN6204 | RD-353 |
| 120 | 90-264VAC | 12V/10A | Dual Switch Flyback | FAN6920MR FAN7382 FAN6204 | RD-351 |
| 120 | 90-264VAC | 19V/6.32A | Dual Switch Flyback | FAN6920MR FAN7382 FAN6204 | RD-352 |
| Title | Product | Description |
|---|---|---|
| Deep Burst Mode Operation for Reducing Standby Power Consumption without Additional Circuitry | FAN6756 | Deep burst mode, one of the power innovations of mWSaver™ technology, is a feedback-control mechanism that reduces standby power consumption in the feedback circuit and switching process by modulating internal parameters of the PWM controller. With this method, the conventional flyback converter topology can be used without additional circuitry. |
| Dual-Switch Quasi-Resonant Flyback Converter | FAN6920MR, FAN7382, FAN6204 | A cost effective and reliable alternative to the LLC resonant converter for energy efficiency regulations. |
| Minimizing Power Losses in the EMI Filter Stage | FSB127H | Innovative technology that minimizes power losses in the EMI filter stage by eliminating the X-cap discharge resistors, while still meeting UL1950 safety requirements. |
|
![]() |